| CPU |
16-Bit Industrial |
| Execution Speed |
Typical Bool Instruction Time: <1μS |
| Word Operation Time: <96μS |
| Arithmetic Operation Time for Integers: <130μS |
| Arithmetic Operation Time for Floating Points: <300μS |
| DI Points |
8XDC24V |
| DO Points |
6XDC24V |
|
|
| User Program Memory |
EEPROM, 8KB |
| Program Backup |
Permanent Storage, Without the Need of Battery//1000 Instructions |
| Memory Area |
Variable Storage Area (V Area): 2KB |
| System Storage Area (SM Area): 300 Bytes |
| Internal Storage Area (M Area): 32 Bytes |
| Data Retention Characteristic |
Configure with the Programming Software: V Area, C (Counter) Area |
| Retention Mode and Period |
Adopt super capacitors and support a retention period of not less than 144 hours upon power failure under normal temperature. |
| Data Backup Characteristic |
Perform Backup Operations VB1648 ~ VB1775 According to User Instructions, 128 Bytes in Total |
| Backup Mode and Time |
EEPROM (Writing Operation for 1 Million Times) Permanent Backup |
| Floating Points |
Supported; the Whole V Area can be Used for Floating Points |
| Programming Language Supported |
Ladder Drawing (LD), Instruction List (IL) |
| Instruction Set |
Basic Instructions: 55; Expansion Instructions: 251 |
| PasswordProtection |
Yes |
| Max I/O Number |
Digital Data: 14 in Total (DI8, DO6); |
| Analog Data: None |
| Counter |
64 |
| Operation Mode of Counter |
Addition, Subtraction |
| Counter Range |
-32768~32767 |
| Counting Value Retention Function |
Yes |
| Timer |
64 |
| 1 ms time Base: 4 |
| 10 ms Time Base: 16 |
| 100 ms Time Base: 44 |
| High speed counter |
2 Single/Dual-Phase High-Speed Counters |
| Where, Single-Phase Counter with a Maximum Frequency of 20KHz |
| Dual-Phase Counter with a Maximum Frequency of 10KHz |
| Pulse output |
2, PTO (Pulse Train Output)/PWM (Pulse Width Modulation Output); |
| Maximum Output Frequency: 20 KHz(Note: the elay output CPU does not have high speed pluse function) |
| Analog Potentiometer |
- |
| Interrupt function |
Timing Interruption: 2, 1ms Resolution; |
| Timer Interruption: T2/T3, 1ms Resolution; |
| Edge Interruption: 4, Rising Edge or Falling Edge Optional; |
| High-Speed Interruption, Communication Interruption |
| Real-time cholck |
0 |
| Number of Connectable Expansion Modules |
- |
| COM Port |
1, RS232 or RS485; |
| Supported Working Modes: Programming, Modbus-RTU (Slave), Free Protocol |
| Equipment Connected with COM Port |
RS232/RS485: PC (For Programming), Third-Party HMI Panel, Third-Party Serial Communication Equipment (For Example, Instruments, Bar Code Reader, etc.) |
| Input Power Supply |
AC85~265V |
| Sensor Load Power Supply |
DC24V, Max. 300 mA |
| Dimensions (L*W*H) |
97X114X70mm |