CPU |
16-Bit Industrial |
Execution Speed |
Typical Bool Instruction Time: <1μS |
Word Operation Time: <96μS |
Arithmetic Operation Time for Integers: <130μS |
Arithmetic Operation Time for Floating Points: <300μS |
DI Points |
8XDC24V |
DO Points |
|
6XRelay |
|
User Program Memory |
EEPROM, 8KB |
Program Backup |
Permanent Storage, Without the Need of Battery//1000 Instructions |
Memory Area |
Variable Storage Area (V Area): 2KB |
System Storage Area (SM Area): 300 Bytes |
Internal Storage Area (M Area): 32 Bytes |
Data Retention Characteristic |
Configure with the Programming Software: V Area, C (Counter) Area |
Retention Mode and Period |
Adopt super capacitors and support a retention period of not less than 144 hours upon power failure under normal temperature. |
Data Backup Characteristic |
Perform Backup Operations VB1648 ~ VB1775 According to User Instructions, 128 Bytes in Total |
Backup Mode and Time |
EEPROM (Writing Operation for 1 Million Times) Permanent Backup |
Floating Points |
Supported; the Whole V Area can be Used for Floating Points |
Programming Language Supported |
Ladder Drawing (LD), Instruction List (IL) |
Instruction Set |
Basic Instructions: 55; Expansion Instructions: 251 |
PasswordProtection |
Yes |
Max I/O Number |
Digital Data: 14 in Total (DI8, DO6); |
Analog Data: None |
Counter |
64 |
Operation Mode of Counter |
Addition, Subtraction |
Counter Range |
-32768~32767 |
Counting Value Retention Function |
Yes |
Timer |
64 |
1 ms time Base: 4 |
10 ms Time Base: 16 |
100 ms Time Base: 44 |
High speed counter |
2 Single/Dual-Phase High-Speed Counters |
Where, Single-Phase Counter with a Maximum Frequency of 20KHz |
Dual-Phase Counter with a Maximum Frequency of 10KHz |
Pulse output |
2, PTO (Pulse Train Output)/PWM (Pulse Width Modulation Output); |
Maximum Output Frequency: 20 KHz(Note: the elay output CPU does not have high speed pluse function) |
Analog Potentiometer |
- |
Interrupt function |
Timing Interruption: 2, 1ms Resolution; |
Timer Interruption: T2/T3, 1ms Resolution; |
Edge Interruption: 4, Rising Edge or Falling Edge Optional; |
High-Speed Interruption, Communication Interruption |
Real-time cholck |
0 |
Number of Connectable Expansion Modules |
- |
COM Port |
1, RS232 or RS485; |
Supported Working Modes: Programming, Modbus-RTU (Slave), Free Protocol |
Equipment Connected with COM Port |
RS232/RS485: PC (For Programming), Third-Party HMI Panel, Third-Party Serial Communication Equipment (For Example, Instruments, Bar Code Reader, etc.) |
Input Power Supply |
AC85~265V |
Sensor Load Power Supply |
DC24V, Max. 300 mA |
Dimensions (L*W*H) |
97X114X70mm |